Secondary Installation
QUALIFIED INSTALLERS ONLY
O
PTIONAL
 F
AN
 K
IT
 I
NSTALLATION
:
If the Retreat is installed, the burner and valve assemblies may need to be removed. If the Retreat is not 
installed the fan can be installed under the firebox, or through an access hole at the lower rear of the 
unit.
WARNING:  The  electrical  grounding  instructions  must  be  followed.  The  fan  should  be    properly 
grounded.
Kit Contents:
This  kit  includes  a  fan  assembly,  a  wiring  harness,    a  temperature  sensor,  fan  control  dial,  two  (2) 
grommets, and two (2) 8-32 x 3⁄4”  bolts.
Please ensure that your fan kit has not been damaged. If so, contact your dealer, distributor, or courier 
company before starting this installation.
O
PTIONAL
 F
AN
 K
IT
 I
NSTALLATION
 T
HROUGH
 F
RONT
 
OF
 R
ETREAT
:
Figure 46.  Wiring Diagram For Fan Control.
The  optional  fan  is  thermostatically 
controlled  and  it  will  not  operate  if  the 
appliance  is  cold.  A  few  minutes  after 
the appliance is lit and the variable speed 
control is set at a desired setting, the fan 
will  automatically  turn  on.  The  fan  will 
automatically turn off a few minutes after 
the appliance is shut off.
The fireplace must be electrically connected 
and  grounded  in  accordance  with  local 
codes  or,  in  the  absence  of  local  codes, 
with  the  current  CSA  C22.1  Canadian 
Electrical  Code  Part  1,  Safety  Standards 
For Electrical Installations, or The National 
Electrical Code ANSI / NFPA 70 in the US.
CAUTION: When servicing controls, label 
all  wires  prior  to  disconnection.  Wiring 
errors can cause improper and dangerous 
operation.  Verify  proper  operation  after 
servicing.
Fan Control
Black
Black
Black
Long
Black
Short
Black
Electrica