Enviro ENVIRO User Manual

Page of 42
2. Start the pilot by pressing the gas control knob and turning it to PILOT.  
While holding the gas control knob in, press the piezo ignitor several times 
until the pilot light starts. Hold the gas control knob in for 30 seconds. 
Check that the pilot has fully engulfed the thermocouple assembly (see 
Figure 3).
3. Start the main burner by turning the gas control knob to ON and then 
turn the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.
A
IR
 S
HUTTER
:
The air shutter adjustment lever is above the left side of the control valve (see Figure 4).
The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate 
different altitudes and venting arrangements. Start the pilot and then the burner. Make sure the pilot 
flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly 
fifteen minutes and then examine the flames, compare the flames to Figure 57.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height. 
If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, 
Open/
More Air
Close/
Less A
r
A
i
r
e
e