Rain cap - ensure cap is at
least 2 feet (610mm) above
the roof at the lowest point
Storm collar
Roof flashing
Roof rafter
Fire stop with
Support Collar
Ceiling joist
Vertical vent pipe
Clean out tee with
Pipe adapter
ENVIRO Meridian
NOTE:
All vent sections must maintian 3"
(76 mm) clearances to combustibles.
Installation
I
NSIDE
 V
ERTICAL
 I
NSTALLATIONS
 - F
REESTANDING
:
1.  Choose a stove location that is ideal.  See the section “I
NSTALLATION
 - D
ECIDING
 W
HERE
 
TO
 L
OCATE
 
YOUR
 P
ELLET
 
A
PPLIANCE
.” 
2.  Place the unit on the hearth pad (if installed on a carpeted surface) and space the unit in a manner 
so when the pellet vent is installed vertically, it will be 3” (76 mm) away from a combustible wall.
3.  Locate the center of the fresh air intake pipe on the unit. Match that center with the same point on 
the wall and cut a hole about 2” (51 mm) in diameter.
Figure 27: Inside Vertical Installation. 
4.  Install  the  fresh  air  intake 
pipe.
5.  Install  the  tee  with  clean 
out.
6. 
I
nstall the pellet vent upward 
from there.  When you reach 
the  ceiling,  make  sure  that 
the  vent  goes  through  the 
ceiling  fire  stop.    Maintain 
a  3”  (76  mm)  distance  to 
combustibles  and  keep 
attic  insulation  away  from 
the  vent  pipe.  Maintain  an 
effective vapor barrier.
7.  Finally,  extend  the  pellet 
vent to go through the roof 
flashing.
8.  Ensure  that  the  rain  cap 
is  approximately  24”  (610 
mm) above the roof.
21