TRoUBlEsHooTiNG
  WARNING:  Turn  off  and  unplug  fireplace  and  let  cool  before 
servicing. Only a qualified service person should service and repair 
fireplace.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIbLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor  cable  pinched  or 
wet
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode positioned 
wrong
6. Ignitor electrode broken
1. Gas  supply  turned  off  or 
equipment  shutoff  valve 
closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Depleted gas supply (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by  any  metal  or  tubing. 
Keep ignitor cable dry
3. Replace ignitor cable
4. Replace piezo ignitor
5. Replace pilot assembly
6. Replace pilot assembly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while 
in PILOT position
4. Continue  holding  down 
control knob. Repeat ignit-
ing  operation  until  air  is 
removed
5. Contact  local  propane/LP 
gas company
6. Clean  ODS/pilot  (see 
Cleaning and Maintenance, 
page 20) or replace ODS/
pilot assembly
7. Replace gas regulator
ObSERvED PRObLEM
When ignitor button is pressed, 
there  is  no  spark  at  ODS/
pilot
When ignitor button is pressed, 
there is spark at ODS/pilot but 
no ignition