FMI CDCFNRB User Manual

Page of 32
www.fmiproducts.com
124979-01C
24
TRoUBlEsHooTiNG
Continued
POSSIbLE CAUSE
1. Residues  from  manufac-
turing  processes  and  log 
curing
2. Not enough air
3. Gas regulator defective
1. Turning control knob to HI 
position  when  burner  is 
cold
2. Air in gas line
3. Air  passageways  on  fire-
place blocked
4. Dirty  or  partially  clogged 
burner orifice
1. When heated, vapors from 
furniture polish, wax, carpet 
cleaners, etc. may turn into 
white powder residue
1. Not  enough  combustion/
ventilation air
1. Battery is not installed. Bat-
tery power is low
1. Metal  expanding  while 
heating or contracting while 
cooling
REMEDY
1. Problem will stop after a few 
hours of operation
2. Check  burner  for  dirt  and 
debris.  If  found,  clean 
burner  (see  Cleaning  and 
Maintenance, 
page 20)
3. Replace gas regulator
1. Turn  control  knob  to  LO 
position  and  let  warm  up 
for a minute
2. Operate  burner  until  air  is 
removed  from  line.  Have 
gas  line  checked  by  local 
natural gas company
3. Observe minimum installation 
clearances (see page 10)
4. Clean burner (see Cleaning 
and Maintenance, page 20) 
or replace burner orifice
1. Turn  fireplace  off  when 
using furniture polish, wax, 
carpet  cleaners  or  similar 
products
1. Refer to Air for Combustion 
and  Ventilation  require-
ments (page 6)
1. Replace  9-volt  batteries  in 
receiver and remote control
1. This  is  normal  with  most 
fireplaces.  If  noise  is  ex-
cessive,  contact  qualified 
service person
ObSERvED PRObLEM
Slight  smoke  or  odor  during 
initial operation
Fireplace produces a whistling 
noise when burner is lit
White powder residue forming 
within burner box or on adja-
cent walls or furniture
Moisture/condensation  no-
ticed on windows
Remote does not function
Fireplace produces a clicking/
ticking noise just after burners 
are lit or shut off