Mitsubishi Electronics MR-J4-_B_(-RJ) User Manual

Page of 636
3. SIGNALS AND WIRING 
3 -  20 
 
(2) Timing chart 
(Note 1)
(3 s to 4 s)
95 ms (Note 2)
10 ms
95 ms
Servo-on command accepted
Main circuit
Control circuit
Base circuit
Servo-on command
(from controller)
power supply
ON
OFF
ON
OFF
ON
OFF
 
Note   1.  This range will be "5 s to 6 s" for the linear servo system and fully closed loop system. 
 
  2.  The time will be longer during the magnetic pole detection of a linear servo motor and direct drive motor. 
 
3.3.3 Wiring CNP1, CNP2, and CNP3 
 
POINT 
 
For the wire sizes used for wiring, refer to section 11.9. 
MR-J4-500B(-RJ) or more and MR-J4-500B4(-RJ) or more do not have these 
connectors. 
 
Use the servo amplifier power connector for wiring CNP1, CNP2, and CNP3. 
 
(1) Connector 
(a)  MR-J4-10B(-RJ) to MR-J4-100B(-RJ) 
CNP2
CNP1
CNP3
Servo amplifier
 
Table 3.1 Connector and applicable wire 
Connector Receptacle 
assembly 
Applicable wire 
Stripped 
length [mm] 
Open tool 
Manufa
cturer 
Size Insulator 
OD 
CNP1 06JFAT-SAXGDK-H7.5 
AWG 18 to 14 
39 mm or shorter 
J-FAT-OT 
JST 
CNP2 05JFAT-SAXGDK-H5.0 
CNP3 03JFAT-SAXGDK-H7.5