Remote Control Functions
Table 1  Table of DC Fan Motor Tap Settings (4-way Air Discharge Semi-Concealed type)
Table 2  Table of DC Fan Motor Tap Settings (ceiling-mounted type)
Table 3  Table of DC Fan Motor Tap Settings (1-way Air Discharge Semi-Concealed type)
*  Failure to make this setting may result in 
decreased airflow and condensation.
3. Timer Remote Controller (RCS-TM80BG)
Selecting the DC fan motor tap 
(when setting with the remote controller)
<Procedure> 
Stop the system before performing these steps.
 Press and hold the 
 and 
buttons simultaneously 
for 4 seconds or longer.
 If group control is in effect, press the 
 button and select 
the address (unit No.) of the indoor unit to set. At this time, the 
fan at the indoor unit begins operating.
 Use the temperature setting buttons to select item code “5d.”
 Press the timer time 
 / 
 buttons to select the desired 
setting data.
 * 
 
For item codes and setting data, refer to Table 1 – Table 4.
 Press the 
 button. (The display stops blinking and remains 
lit, and setting is completed.)
 * 
 
If air-blocking material is used, use the same procedure as in 
steps (3) – (5) above and change the setting for item code “62” 
to “0000.”
To change the selected indoor unit, go to step (2).
 Press  the 
 button to return to normal remote controller display.
Setting No.  Remote controller setting data 
Purpose of use, names of accessories 
0000 
(1) 0001 
(3) 0003 
(6) 0006 
Standard (setting at time of shipping) 
High ceiling setting 1 (for standards panel) 
Super long-life filter 
Oil guard panel 
Oil guard panel with raising / lowering grille 
Ammonia deodorant filter 
Optical regeneration deodorant filter 
High ceiling setting 2 (for standards panel) 
Ceiling panel with special raising / lowering grille for high locations 
High performance filter (90% by JIS colorimetric method) 
High performance filter (65% by JIS colorimetric method) 
Air cleaning unit 
Optical regeneration deodorant filter for air cleaning unit 
Deodorant filter 
Air-blocking material (for 3-way air discharge) 
Air-blocking material (when a discharge duct is connected) 
Air-blocking material (for 2-way air discharge) 
Setting No.  Remote controller setting data 
Purpose of use, names of accessories 
0000 
(1) 0001 
(3) 0003 
Standard (setting at time of shipping) 
High ceiling setting 
Super long-life filter 
Ammonia deodorant filter (65% by JIS colorimetric method) 
Optical regeneration deodorant filter 
High performance filter (65% by JIS colorimetric method) 
Deodorant filter (65% by JIS colorimetric method) 
Setting No.  Remote controller setting data 
Purpose of use, names of accessories 
0000 
(1) 0001 
(3) 0003 
Standard (setting at time of shipping) 
Ammonia deodorant filter (65% by JIS colorimetric method) 
Deodorant filter (65% by JIS colorimetric method) 
Optical regeneration deodorant filter 
6
2
1
5
1
4
3
SM830157_W-2WAY_ECO-i.indb   38
SM830157_W-2WAY_ECO-i.indb   38
2007/06/08   14:23:39
2007/06/08   14:23:39