Desa 000 BTU TB103 User Manual

Page of 56
www.desatech.com
119143-01A
6
 
Extension Cord Size Requirement
 
Up to 50 feet (15 m) long, use 18 AWG 
rated cord.
 
51 to 100 feet (15.5 to 30.5 m) long, use 
16 AWG rated cord.
 
101 to 00 feet (30.78 to 61 m) long, use 
14 AWG rated cord.
4.  Plug  extension  cord  into  a  10  volt/60 
hertz, three-hole, grounded outlet.
5.  Open  propane/LP  supply  valve  on 
propane/LP  tank(s)  slowly.  Note:  If  not 
opened slowly, excess-flow check valve 
on propane/LP tank will stop gas flow. If 
this happens, you may hear a click inside 
the regulator assembly. To reset the ex-
cess flow check valve, close propane/LP 
supply valve and open again slowly.
6.  Adjust  variable  Btu  control  knob  fully 
clockwise to LO.
55, 85, 125 Models Only
7.  Press and hold in gas valve button. Heater 
should ignite within a few seconds.
 
Note: If heater fails to ignite, hose may have 
air in it. If so, keep gas valve button pressed 
and wait 0 seconds. Release gas valve 
button and wait 0 seconds for unburned 
fuel to exit heater. Repeat step 6.
8.  After heater ignites, wait 30 seconds. This 
activates  the  automatic  control  system. 
Release the gas control valve button.
170 Models Only
9.  Adjust  thermostat  to  desired  setting.  If 
heater does not start, thermostat setting 
may be too low. Turn thermostat knob to 
higher  position  to  start  heater.  Note:  If 
heater does not start, unplug heater. Wait 
ten  seconds  for  safety  control  to  reset, 
plug in heater, then try again.
all Models
10. When burner remains lit, set heater to the 
desired heat level by turning the variable 
Btu  control  knob  counterclockwise.  If 
burner goes out, turn off gas. Turn vari-
able  Btu  control  knob  fully  clockwise  to 
the lowest position. Check fuel supply. If 
adequate fuel is available, restart heater 
beginning at step 1.
TO STOP heaTer
1.  Tightly close propane/LP supply valve on 
propane tank(s).
.  Wait a few seconds. Heater will burn gas 
left in supply hoses.
3.  Unplug heater.
OPERATION
 warninG: review and un-
derstand  the  warnings  in  the 
Safety Information section, page 
2. They are needed to safely op-
erate this heater. Follow all local 
codes when using this heater.
TO STarT heaTer
1.  Follow  all  installation,  ventilation  and 
safety information.
.  Locate heater on stable and level surface. 
Make sure strong drafts do not blow into 
front or rear of heater.
3.  Plug  power  cord  of  heater  into  a  three-
prong, grounded extension cord. Exten-
sion cord must be at least six feet long. 
Extension cord must be UL listed.
4.  Open  propane/LP  supply  valve  on 
propane/LP  tank(s)  slowly.  Note:  If  not 
opened slowly, excess-flow check valve 
on propane/LP tank will stop gas flow. If 
this happens, you may hear a click inside 
the regulator assembly. To reset the ex-
cess flow check valve, close propane/LP 
supply valve and open again slowly.
5.  Check all connections for leaks.
6.  Close propane/LP supply valve.
INSTALLATION
Continued
Figure 6 - Hose and Inlet Connector 
(Heater may vary from illustration)
Hose
Inlet Connector
Gas Valve 
Button