Desa 000 BTU TB103 User Manual

Page of 56
www.desatech.com
119143-01A
7
TO reSTarT heaTer
If safety control stops gas flow to heater, motor 
will continue to run.
1.  Unplug heater.
.  Wait ten seconds. Plug heater in.
If heater does not restart
A.  Check  supply  valves  (on  propane/LP 
tank). Make sure they are open.
B.  Check fuel level in propane/LP tank(s). If 
fuel level is too low, contact local propane/
LP gas company.
If  heater  still  does  not  restart,  contact  your 
local service center.
STORAgE
 CaUTiOn: disconnect heater 
from propane supply tank(s).
1.  Store propane/LP tank(s) in safe manner. 
See chapter 5 of Standard for Storage and 
Handling of Liquefied Petroleum Gases, 
ANSI/NFPA 58
 and the Natural Gas and 
Propane Installation Code CSA B149.1

Follow all local codes.
2.  Place  plastic  cover  caps  over  brass  fit-
tings  on  inlet  connector  of  heater  and 
hose/regulator assembly. 
3.  Store  in  dry,  clean  and  safe  place.  Do 
not store hose/regulator assembly inside 
heater combustion chamber.
4.  When taking heater out of storage, always 
check inside of heater. Insects and small 
animals  may  place  foreign  objects  in 
heater.  Keep  inside  of  heater  free  from 
combustible and foreign objects.
OPERATION
Continued
MAINTENANCE
  warninG:  never  service 
heater  while  it  is  plugged  in, 
connected  to  propane  supply, 
operating or hot. Severe burns 
and electrical shock can occur.
1.  Keep heater clean. Clean heater annually 
or as needed to remove dust and debris. If 
heater is dirty or dusty, clean heater with 
a damp cloth.
.  Inspect  heater  before  each  use.  Check 
connections  for  leaks. Apply  mixture  of 
liquid  soap  and  water  to  connections. 
Bubbles forming show a leak. Correct all 
leaks at once.
3.  Inspect  hose/regulator  assembly  before 
each use. If hose is highly worn or cut, 
replace.
4.  Have heater inspected yearly by a quali-
fied service agency.
5.  Keep inside of heater free from combus-
tible and foreign objects.