TABLE 10: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
1.5
2
1.5
2
1.5
2
1.5
2
1.5
2
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
38.0
40.0
43.5 45.5
50
50
50
50
2TP04520925
6.8
18.9
38.0
40.0
43.5 45.5
50
50
50
50
2TP04521825
13.5
37.5
54.6
57.1
61.5 64.0
60
60
70
70
2TP04522425
18
50.0
70.2
72.7
77.1 79.6
80
80
80
80
 2TP04523625 
25.5
70.8
96.2
98.7 103.1 105.6 100 100
110
110
None
--
--
38.0
40.0
43.5 45.5
50
50
50
50
2TP04520925
9
21.7
38.0
40.0
43.5 45.5
50
50
50
50
2TP04521825
18
43.3
61.9
64.4
68.8 71.3
70
70
70
80
2TP04522425
24
57.7
79.9
82.4
86.8 89.3
80
90
90
90
 2TP04523625 
34
81.8
110.0 112.5 116.9 119.4 110 125
125
125
None
--
--
  20.7   21.7   22.9   23.9   25   25
  25
  30
2TP04520946
9
11.3
  20.7   21.7   22.9   23.9   25   25
  25
  30
2TP04521846
18
22.6
  30.9   32.2   33.7   34.9   35   35
  35
  35
2TP04522446
24
30.1
  40
  41.2   42.7   44   40   45
  45
  45
 2TP04523646 
34
42.7
  55
  56.2   57.7   59   60   60
  60
  60
None
--
--
  15.1   16.3   16.9   18.1   20   20
  20
  20
2TP04520958
9
9.0
  15.1   16.3   16.9   18.1   20   20
  20
  20
2TP04521858
18
18.1
  24.7   26.2   26.9   28.4   25   30
  30
  30
2TP04522458
24
24.1
  31.9   33.4   34.1   35.6   35   35
  35
  40
 2TP04523658 
34
34.1
  43.9   45.4   46.1   47.6   45   50
  50
  50
*
Maximum HACR breaker of the same AMP size is applicable.
12.8
110.0
1.5
6.2
8.2
5.5
0.0
12.8
110.0
1.5
7.1
54.0
0.8
5.1
44.0
6.2
8.2
3.1
4.1
0.6
2.4
3.6
5.5
0.0
2.2
0.0
460
575
1.8
0.0
Max 
Fuse* 
Size 
(Amps)
Max Fuse* Size 
w/Power 
Exhaust 
(Amps)
FLA
FLA
Actual 
KW
Heater 
Amps
Min. Circuit 
Ampacity 
(Amps)
MCA 
w/Power 
Exhaust 
(Amps)
Supply 
Blower 
Motor FLA
Pwr 
Exh 
Motor
Pwr 
Conv 
Outlet
Electric Heater 
Model No.
Voltage
Compressors
OD Fan 
Motors
208
230
TABLE 11: ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
1.5
2
1.5
2
1.5
2
1.5
2
1.5
2
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
48.0
50.0
53.5 55.5
60
60
60
60
2TP04520925
6.8
18.9
48.0
50.0
53.5 55.5
60
60
60
60
2TP04521825
13.5
37.5
67.1
69.6
74.0 76.5
70
70
80
80
2TP04522425
18
50.0
82.7
85.2
89.6 92.1
90
90
90
100
 2TP04523625 
25.5
70.8
108.7 111.2 115.6 118.1 110 125
125
125
None
--
--
48.0
50.0
53.5 55.5
60
60
60
60
2TP04520925
9
21.7
48.0
50.0
54.2 56.7
60
60
60
60
2TP04521825
18
43.3
74.4
76.9
81.3 83.8
80
80
90
90
2TP04522425
24
57.7
92.4
94.9
99.3 101.8 100 100
100
110
 2TP04523625 
34
81.8
122.5 125.0 129.4 131.9 125 125
150
150
None
--
--
  25.7   26.7   27.9   28.9   30   30
  30
  35
2TP04520946
9
11.3
  25.7   26.7   27.9   28.9   30   30
  30
  35
2TP04521846
18
22.6
  37.2   38.4   39.9   41.2   40   40
  40
  45
2TP04522446
24
30.1
  46.2   47.5
  49   50.2   50   50
  50
  60
 2TP04523646 
34
42.7
  61.2   62.5
  64   65.2   70   70
  70
  70
None
--
--
  19.1   20.3   20.9   22.1   20   25
  25
  25
2TP04520958
9
9.0
  19.1   20.3   21.1   22.6   20   25
  25
  25
2TP04521858
18
18.1
  29.7   31.2   31.9   33.4   30   35
  35
  35
2TP04522458
24
24.1
  36.9   38.4   39.1   40.6   40   40
  40
  45
 2TP04523658 
34
34.1
  48.9   50.4   51.1   52.6   50   60
  60
  60
*
12.8
110.0
1.5
230
1.5
5.5
10.0
6.2
8.2
208
110.0
460
575
12.8
Voltage
Compressors
OD Fan 
Motors
Supply 
Blower 
Motor FLA
Pwr 
Exh 
Motor
Pwr 
Conv 
Outlet
Electric Heater 
Model No.
Max 
Fuse* 
Size 
(Amps)
Max Fuse* Size 
w/Power 
Exhaust 
(Amps)
FLA
FLA
Actual 
KW
Heater 
Amps
Min. Circuit 
Ampacity 
(Amps)
MCA 
w/Power 
Exhaust 
(Amps)
Maximum HACR breaker of the same AMP size is applicable.
6.2
8.2
5.5
10.0
7.1
54.0
0.8
3.1
4.1
2.2
5.0
5.1
44.0
0.6
2.4
3.6
1.8
4.0