York YUHC 07-18 User Manual

Page of 23
22
ENGLISH
TROUBLE SHOOTING GUIDE
Problem
Probable cause
Remedy
A.  The air conditioner does not 
run.
1.  Power failure.
2.  Fuse  blown  or  circuit  breaker 
open.
3.  Voltage is too low.
4.  Faulty contactor or relay.
5.  Electrical connections loose.
6.  Thermostat  adjustment  too  low 
(in heating mode) or too high (in 
cooling mode).
7.  Faulty capacitor.
8.  Incorrect wiring, terminal loose.
9.  Pressure switch tripped.
1.  Wait for power resume.
2.  Replace  the  fuse  or  reset  the 
breaker.
3.  Find the cause and fix it.
4.  Replace the faulty component.
5.  Retighten the connection.
6.  Check thermostat setting.
7.  Find the cause then replace ca-
pacitor.
8.  Check and retighten.
9.  Find the cause before reset.
B.  The outdoor fan runs but the 
compressor will not start.
1.  Motor winding cut or grounded.
2.  Faulty capacitor.
1.  Check  the  wiring  and  the  com-
pressor winding resistance.
2.  Find the cause then replace ca-
pacitor.
C.  There  is  insufficient  heating 
or cooling.
1.  There is a gas leak.
2.  Liquid and gas line insulated to-
gether.
3.  The room was probably very hot 
(cool) when you started the sys-
tem.
1.  Remove  charge,  repair,  evacu-
ate and recharge.
2.  Insulate them separately.
3.  Wait while unit has enough time 
to cool the room.
D.  The  compressor  runs  con-
tinuously.
1.  Thermostat  adjustment  too  low 
(in heating mode) or too high (in 
cooling mode).
2.  Faulty fan.
3.  Refrigerant charge too low, leak.
4.  Air or incondensables in refriger-
ant circuit.
1.  Check thermostat setting.
2.  Check condenser air circulation.
3.  Find leak, repair and recharge.
4.  Remove  charge,  evacuate  and 
recharge.
E.  The  compressor  starts  but 
shuts down quickly.
1.  Too much or too little refrigerant. 
2.  Faulty compressor.
3.   Air or incondensables in refriger-
ant circuit.
4.  Changeover  valve  damaged  or 
blocked open (heat pump unit).
1.  Remove  charge,  evacuate  and 
recharge.
2.  Determine the cause and replace 
compressor.
3.  Remove  charge,  evacuate  and 
recharge.
4.  Replace it.
F.  Clicking sound is heard from 
the air conditioner.
In  heating  or  cooling  operation  any 
plastic  parts  may  expand  or  shrink 
due to a sudden temperature change 
in  this  event,  a  clicking  sound  may 
occur.
In  heating  or  cooling  operation  any 
plastic  parts  may  expand  or  shrink 
due to a sudden temperature change 
in  this  event,  a  clicking  sound  may 
occur.
J368-EN.indd   22
2/1/07   9:41:37 AM