York D1EG User Manual

Page of 32
036-21411-002-A-0204
6
Unitary Products Group
Not ARI required
TABLE 1: CAPACITY RATINGS - COOLING / ELECTRIC HEATING
MODEL
ARI RATINGS
1
NOMINAL ELECTRIC HEAT CAPACITY
2
 (kW)
COOLING CAPACITY 80 / 67-95°F
SOUND
RATING
3
(dBels)
MBH
SEER
4
EER
5
240V
480V
600V
DEE036
42.5
11.5
10.10
86.0
5, 7, 10, 15 & 
20
7, 10, 15 & 20
10, 15, & 20
DEE048
49.5
11.0
10.0
86.0
5, 7, 10, 15 & 
20
7, 10, 15 & 20
10, 15, & 20
DEE060
58.5
11.0
10.05
86.0
5, 7, 10, 15, 
20, & 30
7, 10, 15, 10, 
& 30
10, 15, 20 & 
30
1.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
2.
Heaters are available as accessories - all with single point power supply
3.
Rated in accordance with ARI Standard 270.
4.
SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling 
divided by the total electric power input in watt-hours during the same period.
5.
EER = Energy Efficiency Ratio - the cooling capacity in BTU’s per hour (BTUH) divided by the power input in watts at any given 
set of rating conditions, expressed in BTUH per watt (BTUH/watt).
TABLE 2: CAPACITY RATINGS - COOLING / GAS HEATING
MODEL
ARI RATINGS
1
GAS HEAT CAPACITY
COOLING CAPACITY 80 / 
67-95°F
SOUND
RATING
2
(dBels)
INPUT
(MBH)
OUTPUT
(MBH)
AFUE
3
 (%)
S.S.E.
4
 (%)
TEMP.
RISE
(°F)
GASE LINE SIZE
(in. O.D.)
MBH
SEER
5
EER
6
DEG036N040
42.5
11.5
10.1
86
50
40
80.9
81.6
15-45
1/2
DEG036N079
42.5
11.5
10.1
86
100
79
80.5
80.8
40-70
1/2
DEG048N060
49.5
11.0
10.0
86
75
59
80.9
81.6
25-55
1/2
DEG048N099
49.5
11.0
10.0
86
125
99
80.3
80.6
45-75
1/2
DEG060N079
58.5
11.0
10.05
86
100
79
80.5
80.8
25-55
1/2
DEG060N099
58.5
11.0
10.05
86
125
99
80.3
80.6
35-65
1/2
1.
Ratings are in accordance with ARI Standard 210.
2.
Sound ratings are in accordance with ARI Standard 270.
3.
AFUE = Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure.
4.
S.S.E. = Steady State Efficiency (Percent Output).
5.
SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling 
divided by the total electric power input in watt-hours during the same period.
6.
EER = Energy Efficiency Ratio - the cooling capacity in BTU’s per hour (BTUH) divided by the power input in watts at any given 
set of rating conditions, expressed in BTUH per watt (BTUH/watt).
TABLE 3: SOUND POWER RATINGS
1
UNIT
SIZE
CFM
ESP
BLOWER
SOUND POWER (dB 10
-12
 WATTS)
OCTAVE BAND CENTERLINE FREQUENCY (Hz)
SWL
dB(A)
dBA
@ 10Ft
2
IWG
SPEED
kW
63
125
250
500
1000
2000
4000
8000
036
1200
0.60
LOW
0.60
84
84
74
67
69
62
57
52
74
41
048
1600
0.55
HIGH
0.80
85
85
75
68
70
63
58
53
75
42
060
2000
0.45
HIGH
1.00
86
86
76
69
71
64
59
54
76
43
1.
These values have been accessed using a model of sound propagation from a point source into the hemispheric free field.  The 
dBA values provided are to be used fro reference only.  Calculation of dBA values cover matters of system design and the fan 
manufacture has no way of knowing the details of each system.  This constitutes an exception to any specification or guarantee 
requiring a dBA value or sound data in any other form than sound power level ratings.
2.
At a distance of 10 feet from the blower.
Not ARI required