York H*RA018 THRU 060 User Manual

Page of 20
036-21121-002 Rev. A (0602)
Unitary Products Group
3
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED 
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 PH 10 SEER AC WITH N1AH / G2FD
H1RA018S06
N1AHB0806
2,5,8,10
17
G2FD024S17
650
19.0
14.1
10.50
-
9.80
H1RA024S06
N1AHB0806
2,5,8,10
17
G2FD024S17
800
24.4
18.1
10.50
-
9.55
N1AHB0806
2,5,8,10
17
G2FD030S17
850
25.0
18.5
10.60
-
9.65
H2RA030S06
N1AHB1206
5,8,10,15,19
17
G2FD030S17
1000
29.0
21.5
10.30
-
9.45
N1AHB1206
5,8,10,15,19
17
G2FD036S17
1000
30.0
22.2
10.50
-
9.65
H2RA036S06
N1AHB1206
5,8,10,15,19
17
G2FD036S17
1200
33.8
25.0
10.00
-
9.20
N1AHB1206
5,8,10,15,19
17
G2FD046S17
1200
34.4
25.5
10.15
-
9.30
H1RA042S06
N1AHC1606
5,8,10,15,20
21
G2FD042S21
1400
39.5
29.2
10.00
-
9.00
N1AHC1606
5,8,10,15,20
21
G2FD048S21
1450
41.0
30.3
10.10
-
9.15
H1RA048S06
N1AHC1606
5,8,10,15,20
21
G2FD048S21
1600
46.0
34.0
10.10
-
9.50
N1AHD2006
8,10,15,20,25,30
24
G2FD060S24
1600
47.0
34.8
10.40
-
9.70
H3RA060S06
N1AHD2006
8,10,15,20,25,30
24
G2FD060S24
1800
56.0
40.2
10.50
-
9.35
3 PH 10 SEER AC WITH N1AH / G2FD
H1RA036 S(25,46)
N1AHB1246
10,15
21
G2FD036S17
1200
33.8
25.0
10.00
-
9.20
N1AHB1246
10,15
21
G2FD042S21
1400
40.0
30.1
10.00
9.05
H1RA042S(25,46)
N1AHC1646
10,15
21
G2FD042S21
1400
39.5
29.2
10.00
-
9.00
N1AHC1646
10,15
24
G2FD048S21
1450
41.0
30.3
10.10
-
9.15
H1RA048S(25,46)
N1AHC1646
10,15
21
G2FD048S21
1600
46.0
34.0
10.10
-
9.50
N1AHD2046
10,15,29
24
G2FD048S24
1600
24.6
34.0
10.10
-
9.50
N1AHD2046
10,15,29
24
G2FD048S24
1600
46.0
34.0
10.10
-
9.50
H1RA060S(25,46)
N1AHD2046
10,15,29
24
G2FD060S24
1750
58.5
39.8
10.00
-
10.25
1 PH 10 SEER AC / F2RP / RC / FC 
4
,
5
H1RA018S06
F2RC/F2FC024
5,8,10
18
-
650
17.4
12.9
10.00
-
9.00
F2RP/F2FP018
2,5,8
18
-
650
17.4
12.3
10.00
-
9.00
F2RP/F2FP024
5,8,10
18
-
650
17.4
12.9
10.00
-
9.00
H1RA024S06
F2RP/F2FP024
5,8,10
18
-
800
23.4
17.3
10.00
-
9.00
F2RP/F2FP030
5,8,10,15
18
-
800
23.6
17.5
10.00
-
9.10
H2RA030S06
F2RP/F2FP030
5,8,10,15
18
-
1000
28.4
21.0
10.00
-
9.50
F2RP/F2FP036
5,8,10,15,19
21
-
1000
28.0
20.0
10.00
-
9.00
H2RA036S06
F2RC/F2FC036
5,8,10,15
21
-
1200
33.6
21.5
10.00
-
9.10
F2RP/F2FP036
5,8,10,15,19
21
-
1200
34.4
25.2
10.20
-
9.30
F2RP/F2FP042
5,8,10,15
21
-
1200
34.4
25.2
10.15
-
9.20
H1RA042S06
F2RP/F2FP042
5,8,10,15
21
-
1400
39.5
28.9
10.00
-
9.00
F2FP048
5,8,10,15,20,25
24
-
1400
40.5
30.0
10.00
-
9.20
H1RA048S06
F2FP048
5,8,10,15,20,25
24
-
1600
45.5
33.7
10.00
-
9.15
F2FP060
5,8,10,15,20,25
24
-
1600
46.5
34.4
10.00
-
9.70
H3RA060S06
F2FP060
5,8,10,15,20,25
24
-
1800
56.0
41.0
10.00
-
9.15
3 PH 10 seer AC with F2RP / FP
H1RA036 S(25,46)
F2RC/F2FC036
5,8,10,15
21
-
1200
33.6
25.2
10.00
-
9.10
H1RA042S(25,46)
F2RP/F2FP042
5,8,10,15
21
-
1400
39.0
29.2
10.00
-
9.00
F2FP048
5,8,10,15,20,25
24
-
1400
40.5
30.4
10.00
-
9.00
H1RA048S(25,46)
F2FP048
5,8,10,15,20,25
24
-
1600
45.5
33.7
10.00
-
9.15
H1RA060S(25,46)
F2FP060
5,8,10,15,20,25
24
-
1750
58.5
39.8
10.00
-
9.80
3 PH 10 seer AC WITH K4EV 
6
H1RA076S25,46
K4EV090
10,16,26,36
22
--
2600
73.5
--
--
--
10.00
H1RA090S25,46
K4EV090
10,16,26,36
22
--
3280
53.8/
89.0
--
--
--
9.63/
9.30
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240. 
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power 
input in watt-hours during the same period.
1
G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2
Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.
3
TXV = Use 1TV700 Series Kit.
4
To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
models. All ratings remain the same.
5
FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.
6
H*BA-(T,W)090 is field convertible to two stage operation. Its IPLV = 11.2.
— = Not Applicable.