Heatiator BCDV36 User Manual

Page of 28
01-03
15
33606 Rev D
BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
H. UTILITIES
1. GAS  LINE  CONNECTION
Open the control access panel as shown in Figure 24.
See  Figure  25  to  connect  the  gas  line  properly. All
connections  must  be  checked  for  leaks  with  a  soap
and  water  solution  or  a  leak  detector.  Bleed  the  gas
line to extract any air that may have been trapped inside
the pipe.
This appliance is supplied with a 3/8” flare connection
to the gas valve. Installation of flexible connector and/
or manual gas valve must conform to local codes. In
the absence of local codes, with the National Flue Gas
Code ANSI Z223.1-latest edition in the U.S.A. and the
CAN/CGA B149 Installation Codes in Canada.
This  appliance  has  been  tested  for  installation  of  a
manual shutoff valve in the bottom compartment of the
appliance.
The  Commonwealth  of  Massachusetts  requires  this
to be a T-handle type manual shutoff valve.
Note: 
This appliance and its manual shutoff valve must
be disconnected from the gas supply piping system dur-
ing any pressure testing of that system at test pressures
in  excess  of  1/2  psi  (3.5  kPa).  The  appliance  must  be
isolated from the gas supply piping system by closing its
manual shutoff valve during any pressure testing of the
gas  supply  piping  system  at  test  pressures  equal  to  or
less than 1/2 psi (3.5 kPa).
2. GAS  PRESSURE
On the standing pilot gas control valve, a pressure tap
is included on the front face of the valve.
Table 2 shows the optimum gas pressure information.
Consult  your  local  gas  company  for  assistance  in
determining the proper orifice for your altitude or refer
to ANSI Z223.1 - latest edition.
Table 2 - Gas Information for Standing Pilot Appliances
Figure 26 - Conversion Kit
6
3
V
D
C
B
.
G
.
N
.
P
.
L
f
o
e
s
o
p
r
u
P
r
o
f
e
r
u
s
s
e
r
P
t
e
l
n
I
m
u
m
i
n
i
M
t
n
e
m
t
s
u
j
d
A
t
u
p
n
I
*
5
.
4
*
1
1
e
r
u
s
s
e
r
P
t
e
l
n
I
m
u
m
i
x
a
M
*
5
.
0
1
*
4
1
e
r
u
s
s
e
r
P
d
l
o
fi
n
a
M
l
a
m
it
p
O
*
5
.
3
*
0
1
e
r
u
s
s
e
r
P
d
l
o
fi
n
a
M
m
u
m
i
n
i
M
*
7
.
1
*
4
.
5
H
/
U
T
B
t
u
p
n
I
m
u
m
i
x
a
M
0
0
0
,
0
2
0
0
5
,
8
1
s
e
h
c
n
I
-
e
z
i
S
e
c
if
ir
O
9
8
0
.
0
2
5
0
.
0
n
m
u
l
o
C
r
e
t
a
W
f
o
s
e
h
c
n
I
*
Figure 24 - Control Access Panel
Figure 25 - Gas Line
Optional: Seal around the gas line to prevent cold air leakage.
(Right Side)
3. GAS  CONVERSIONS
Natural or propane gas conversions necessary to meet
the  application  need  to  be  made  by  a  qualified
technician  using  Hearth  &  Home  Technologies
specified  and  approved  parts.
In the event your appliance must be converted to use
propane, you must use a CKP Conversion Kit. To be
converted  to  use  natural  gas,  you  must  use  a  CKN
Conversion Kit. See Figure 26.
WARNING!
This valve has been preset at the factory. Altering
settings may result in fire hazard or bodily injury.