DFX & DBX Series Vent Free Fireplaces
IMPORTANT SAFETY INFORMATION
0.  Input ratings are shown in BTU per hour and are for 
elevations up to ,000 feet. For elevations above ,000 
feet, input ratings should be reduced 4 percent for each 
1,000 feet above sea level. Refer to the National Fuel 
Gas Code.
1.  The appliance and its appliance main gas valve must 
be disconnected from the gas supply piping system 
during any pressure testing of that system at test pres-
sures in excess of 1/ psig (3.5 kPa).
.  The appliance must be isolated from gas supply piping 
system by closing its equipment shutoff valve during 
any pressure testing of the gas supply piping system 
at test pressures equal to or less than 1/ psig (3.5 
kPa).
3.  Do not use this room heater if any part has been under 
water. Immediately call a qualified service technician 
to inspect the room heater and to replace any part of 
the control system and any gas control which has been 
under water.
4.  Never burn solid fuels in a fireplace where a unvented 
room heater is installed.
5.  Always  have  a  fireplace  screen  in  place  when  the 
appliance is in operation and, unless other provisions 
for combustion air are provided, the screen must have 
an opening(s) for induction of combustion air.
THIS  APPLIANCE  MAY  BE  INSTALLED  IN  AN 
AFTERMARkET,  PERMANENTLY  LOCATED, 
MANUFACTURED (MOBILE) HOME, WHERE NOT 
PROHIBITED BY LOCAL CODES.
THIS APPLIANCE IS ONLY FOR USE WITH THE 
TYPE  OF  GAS  INDICATED  ON  THE  RATING 
PLATE. THIS APPLIANCE IS NOT CONVERTIBLE 
FOR USE WITH OTHER GASES.
CODES
Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE 
ANSI Z3.1 or NFPA54 which can be obtained from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
or
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 069