Enviro EF3 User Manual

Page of 43
Installation
H
ORIZONTAL
 E
XHAUST
 T
HROUGH
 W
ALL
 I
NSTALLATION
 - F
REESTANDING
:
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, 
or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired, 
the installation shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and 
Equipment. Only use venting of L or PL type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm).
1.  Choose  a  location  for  your  stove  that  meets  the  requirements  stated  in  this  manual  and  allows 
installation with the least amount of interference to house framing, plumbing, wiring, etc.
2. Install a non-combustible hearth pad (where necessary).
Figure 23: Straight through wall Installation. 
Non-combustible
floor protection.
Existing floor
(combustible)
6"
(15 cm)
2"
(5 cm)
Wall
thimble
Fresh air
intake
Rodent
mesh cap
45°
elbow
12"
(30.5 cm)
3.  Place  the  appliance  15”  (37.5  cm) 
away from the wall. If the stove is 
to be set on a hearth pad, set the 
unit on it. 
4. Locate  the  center  of  the  exhaust 
pipe on the stove. Extend that line 
to the wall. Once you have located 
the center point on the wall, refer to 
pellet vent manufacturer installation 
instructions for correct hole size and 
clearance to combustibles.
5. Install  the  wall  thimble  as  per  the 
instructions written on the thimble. 
Maintain an effective vapour barrier 
in  accordance  with  local  building 
codes.
6. Install  a  length  of  3”  (76  mm)  or 
4”  (101  mm)  vent  pipe  into  the 
wall  thimble.  The  pipe  should 
install  easily  into  the 
thimble.
7.  Install  the  fresh  air 
intake  (see  O
UTSIDE
 
F
RESH
 A
IR
 C
ONNECTION
).
8. Connect  the  exhaust 
vent  pipe  to  the 
exhaust 
pipe 
on 
the  stove.  Seal  the 
connection  with  high 
temperature silicone.
9. Push the stove straight 
back, 
leaving 
minimum of 2” (5 cm) 
clearance  from  the 
back  of  the  stove  to 
the wall.  Seal the vent 
pipe  to  the  thimble 
with high temperature 
silicone.
Exhaust Tube
3" (75mm) or 4" (100mm) "PL" or "L" vent
Wall Thimble
45° Elbow with screen or
Termination Cap
Fresh Air Intake
High Temperature RTV
Silicone Required
Figure 24: Venting to use with straight through wall Installation. 
20