Enviro EF3 User Manual

Page of 43
Installation
I
NSIDE
 V
ERTICAL
 I
NSTALLATIONS
 - F
REESTANDING
:
1.  Choose a stove location that is ideal.  See the section “D
ECIDING
 W
HERE
 
TO
 L
OCATE
 
YOUR
 P
ELLET
 A
PPLIANCE
.” 
Non-combustible
floor protection.
Existing floor
(combustible)
6"
(15 cm)
3" (7.5 cm)
clearance
Use wall thimble
or ceiling firestop
Rain cap
Flashing
24"
(61 cm)
3"
(7.5 cm)
Tee with
cleanout
Fresh air
intake
6"
(15 cm)
Figure 27: Inside Vertical Installation. 
2.  Place  a  non-combustible  hearth 
pad where necessary.
3.  Place  the  unit  on  the  hearth  pad 
(if installed on a carpeted surface) 
and space the unit in a manner so 
when  the  pellet  vent  is  installed 
vertically,  it  will  be  3”  (7.6  cm) 
away from a combustible wall.
4.  Locate the center of the fresh air 
intake pipe on the unit. Match that 
center with the same point on the 
wall and cut a hole about 1 5⁄8” (41 
mm) in diameter.
5.  Install the fresh air intake pipe.
6.  Install the tee with clean out.
7. 
I
nstall  the  pellet  vent  upward 
from there.  When you reach the 
ceiling,  make  sure  that  the  vent 
goes through the ceiling fire stop.  
Maintain  a  3”  (7.6  cm)  distance 
to  combustibles  and  keep  attic 
insulation  away  from  the  vent 
pipe.  Maintain  an  effective  vapor 
barrier.
8.  Finally,  extend  the  pellet  vent  to 
go through the roof flashing.
9.  Ensure  that  the  rain  cap  is 
approximately  36”  (900  mm) 
above the roof.
O
UTSIDE
 V
ERTICAL
 I
NSTALLATIONS
 - F
REESTANDING
:
To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “I
NSIDE
 V
ERTICAL
 I
NSTALLATIONS
 
- F
REESTANDING
” section and then finish it by performing the following (refer to Figure 28).
1.  Install a tee with clean out on the outside of the house.
2. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent 
straight and secure.
3. Install ceiling thimble and secure the flashing as you go through the roof.
4. Ensure that the rain cap is approximately 36” (91.5 cm) above the roof.
22