Operations Commands
Operations commands allow more flexible and direct control of the projector.  The syntax 
for operations commands is as follows:
op <operation> <command>[CR]
(Precede 
<operation> and <command> with a space.)
The command type can be one of 5 functions:  
asp.16.9
(none)
0x9E
0xDE
Apply 16:9 aspect ratio to the active 
source.
asp.4.3
(none)
0x9F
0xDF
Apply 4:3 aspect ratio to the active source.
asp.lett
(none)
0xA0
0xE0
Apply Letterbox aspect ratio to the active 
source.
asp.narr
(none)
0xA1
0xE1
Apply 4:3 Narrow aspect ratio to the active 
source.
pip.sw
0xA3
0xE3
Switch to next “PIP Select” state.
pip.1
(none)
0xA4
0xE4
Change “PIP Select” to source 1.
pip.2
(none)
0xA5
0xE5
Change “PIP Select” to source 2.
pip.3
(none)
0xA6
0xE6
Change “PIP Select” to source 3.
pip.4
(none)
0xA7
0xE7
Change “PIP Select” to source 4.
pip.5
(none)
0xA8
0xE8
Change “PIP Select” to source 5.
pip.off
(none)
0xA9
0xE9
Change “PIP Select” to off.
pip.swap
0xAA
0xEA
Swap the PIP image with the active source 
image.
pow.tog
(none)
0xAC
0xEC
Toggles between power on and power off.
lit.tog
0xAD
0xED
Activates remote backlighting only when 
pressed momentarily.  When held for five 
seconds or more, the IR code for toggling 
the projector I/O panel light is transmitted.
Table 6-1. Serial Command Key Names and IR Codes (continued)
RS232 
Keyname
Remote Button
IR Code
Description
Set 1
Set 2
PIP
SWAP
LIGHT
Operations Control Commands
Function
Command
Action on unit
Set
= <value>
Makes the unit take that value.
Get
?
Asks what the current value is.
Increment
+
Adds 1 to the current value.