Table 6-2 lists the valid operations commands. For all but Execute functions, the response 
from the projector is the command and “= <value>” where <value> is the current value or 
“NA” if the value is not available. For Execute functions the response is the same 
command.  All responses are in UPPERCASE.
Some operations command examples:
Input: 
op bright ? [CR]
Response: 
OP BRIGHT = 100 [CR]
Input: 
op bright + [CR]
Response: 
OP BRIGHT = 101 [CR]
Input: 
op bright = 127 [CR]
Response: 
OP BRIGHT = 127 [CR]
Input: 
op bright - [CR]
Response: 
OP BRIGHT = 126 [CR]
Input: 
op resync [CR]
Response: 
OP RESYNC [CR]
Input: 
op sharp.mode = 1 [CR]
Response: 
OP SHARP.MODE = 1 [CR]
Input: 
op sharp.simple = 50 [CR]
Response: 
OP SHARP.SIMPLE = NA [CR]
Input: 
op sharp.simple ? [CR]
Response: 
OP SHARP.SIMPLE = NA [CR]
The last three commands show what happens when a control is grayed out.  In this case, 
the sharpness mode was set to advanced (value = 1) and then the simple sharpness slider 
was attempted to be adjusted and queried.  The response was “NA” or not available.  
Decrement
-
Subtracts 1 from the current value.
Execute
(none)
Performs an action such as a reset.
Table 6-2. Serial Commands 
Operation
Commands
Values
Notes
aspect
= ?
0 = 16:9
1 = Letterbox
2 = 4:3
3 = 4:3 Narrow
4 = Native
memory
= ?
0 = User Memory 1
1 = User Memory 2
2 = ISF Day
3 = ISF Night
4 = Default
? only returns a value if 
ISF Day or ISF Night is 
active, otherwise it returns 
NA