Troubleshooting Tips
Table 5-1 provides some general guidelines for troubleshooting problems you may 
encounter with the LS-10d. If you encounter an issue not described here, please contact 
Runco Technical Support. 
Table 5-1. Troubleshooting Chart
Symptom
Possible Cause(s)
Solution
The projector does not turn 
on after initial installation. The 
power LED on the front of the 
DHD Controller lights red after 
you press the power button. 
• The DHD Controller is 
connected to the LS-10d 
incorrectly or not at all. 
• The LS-10d is not plugged 
in or the AC outlet is not 
active. 
• Verify the HDMI cable 
connection from the DHD 
Controller to the LS-10d. 
Do not use a DVI cable 
for this connection. 
• Ensure that the LS-10d is 
plugged in and that the AC 
outlet is active. 
The projector and DHD Con-
troller are both on, but there is 
no video image on-screen. 
• Incorrect source selection. 
• Source component is not 
turned on. 
• Select the correct source. 
• Turn on the source. 
Image is too bright and/or 
lacks definition in the bright 
areas of the image. 
• Contrast is set too high. 
• Lower the contrast setting. 
Image appears “washed out” 
and/or dark areas appear too 
bright. 
• Brightness is set too high. 
• Lower the brightness 
setting. 
Colors in the image are 
swapped; for example, reds 
appear blue or vice versa. 
• The Red/Pr, Green/Y or 
Blue/Pb outputs from the 
source are connected to 
the wrong inputs on the 
DHD Controller. 
• Ensure that the source 
outputs are connected to 
the correct DHD Controller 
input. 
Image geometry is incorrect.
• Incorrect aspect ratio 
selection. 
• Select the aspect ratio that 
best matches the source 
image and screen size 
(refer to Table 4-1). 
The projector will not turn 
back on after it was powered 
down, or the image disap-
pears during operation. 
• The projector will not turn 
on for two minutes after 
power-down, to protect 
the lamp. 
• The lamp has failed. 
• Wait two minutes until the 
LED at the front of the 
DHD Controller turns red. 
• Replace the lamp.