Response: 
ACK:INPUT = 0 [CR]
Input: 
op phase = 50 [CR]
Response: 
ERR:NA [CR]
Input: 
op phase ? [CR]
Response: 
ERR:NA [CR]
The last three commands show what happens when a control is unavailable.  In this case, 
the source was set to “HDMI 1” (value = 0) and then the phase slider was attempted to be 
adjusted and queried.  The response was “NA” or not available.  
Table 6-2. Serial Commands 
Operation
Commands
Values
Notes
powon
(execute)
Power on command
powoff
(execute)
Power off command
3d.mode
= ?
0 = Auto
1 = Side-by-side
2 = Top-and-bottom
3 = Off
3d.chswap
= ?
0 = Normal
1 = Reversed Eyes
aspect
= ?
0 = 16:9
1 = Letterbox
2 = 4:3
3 = VirtualWide
4 = Cinema
5 = Virtual Cinema
recall.mem
= ?
0 = Custom 1
1 = Custom 2
2 = ISF Day
3 = ISF Night
4 = Default
? only returns a value if ISF Day or 
ISF Night is active, otherwise it 
returns NA
save.mem
=
0 = Custom 1
1 = Custom 2
save.isf
=
0 = ISF Day
1 = ISF Night
brightness
= ?
0 - 200
contrast
= ?
0 - 200
saturation
= ?
0 - 200
hue
= ?
0 - 200
sharpness
= ?
0 - 200
nr
= ?
0 - 200
overscan
= ?
0 = Off
1 = Crop
2 = Zoom