Runco X-200i User Manual

Page of 118
Runco X-200i Series Installation/Operation Manual
91 
PRE
L
IMINAR
Y
RS-232 Error Codes
If an 
errcode ? command returns one of the following values, you have encountered a 
likely system error requiring the attention of a qualified service technician. Try resetting the 
projector by powering it off, allowing it to cool and powering it on again. Refer to Table 6-3 
and contact your dealer if the problem persists. 
The specific code number identifies the source of the error detected, and is particularly 
useful in cases where the projector is far away. For example, the code “21” means that 
Fan 1 has failed.
Table 6-3. RS-232 Error Codes 
Error Code
LED Indication
Description
1
Inlet NTC thermal sensor is over temperature. 
3
Lamp 1 over temperature. 
7
Ballast 1 over temperature. 
20
Fan failure upon system power-up.
21
Fan 1 locked.
22
Fan 2 locked.
23
Fan 3 locked.
24
Fan 4 locked.
25
Fan 5 locked.
26
Fan 6 locked.
27
Fan 7 locked.
28
Fan 8 locked.
29
Fan 9 locked.
40
Lamp failed to ignite (three attempts) upon system 
power-up. 
41
Lamp failed during operation. 
42
Ballast UART communication failure. 
50
Lamp door is open. 
52
PCF8575 external GPIO communication failure. 
53
System I2C communication failure.
54
Write EEPROM failure. 
60
DDP3021 communication failure upon system power-up. 
61
Video board initialization failure. 
62
DCF FPGA communication failure upon system power-up. 
63
OSD loading error. 
64
Scaler (GF9452) is not responding.