6.2 
Using Discrete IR 
Codes
The X-200i accepts commands in the form of IR signals that conform to the NEC protocol. 
Each X-200i remote control button has an NEC control code associated with it. 
As shown in Table 6-1, there are two complete sets of remote codes (designated “Set 1” 
and “Set 2”).  Through the on-screen menu, the projector can be configured to use either 
set.  The reason for two sets is to allow control of more than one product in the same 
room without interference. The remote control can also be configured to use either code 
set (refer to Infrared Remote on page 71).
You can use these codes to program a third-party, “universal” remote control unit to work 
with the X-200i. These third-party products usually come with a computer software 
application for this purpose. For more information, consult the documentation provided 
with the remote control unit. 
IR Command Protocol
The IR control codes have the following characteristics:
• Each code consists of the following:
• A leader pulse (a modulated pulse of 9 ms followed by a non-modulated pulse of 
4.5 ms);
• 16 address bits - 0x06 0xF9 (binary 00000110 11111001); 
• 16 data bits: eight (8) bits for the command followed by the logical inverse of the 
command; and
• An end pulse (a modulated pulse of 0.56 ms, similar to the modulated pulse in the 
‘0’ and ‘1’ bits).The end of the modulated pulse constitutes the end of the data 
transmission. 
• The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle. 
• Commands are sent at a maximum rate of 9 Hz.
For example, here is the NEC control code for the ON (
) button on the X-200i remote 
control unit (using Code Set 1):  
Figure 6-1 shows the pulse train for this command. 
Figure 6-1. NEC Protocol Message Format
Hex
06
F9
01
FE
Binary
00000110
11111001
00000001
11111110
Function
Address Byte 1
Address Byte 2
Command
Command
(Logical Inverse)
9 ms
13.5 ms
27 ms
27 ms
Address Byte 1
Leader Pulse
Address Byte 2
Command Byte
Command Byte (logical inverse)
0 0 0 0 0 1   1   0 1   1   1   1   1   0 0 1
0 0 0 0 0 0 0 1
1   1   1   1   1   1   1   0
4.5 ms