PRE
L
IMINAR
Y
Colors in the image are 
swapped; for example, reds 
appear blue or vice versa. 
• The  Red/Pr,  Green/Y  or 
Blue/Pb outputs from the 
source are connected to 
the wrong inputs on the 
X-200i.
• Ensure that the source 
outputs are connected to 
the correct X-200i input. 
ISSUE LED is flashing red 
(one short flash). 
• The lamp has failed or 
exceeded its usage life.
• Replace the lamp with a 
new one. 
ISSUE LED is flashing red 
(two short flashes). 
• The lamp cover is open.
• Close the lamp cover.
ISSUE LED is flashing red 
(four short flashes).
• X-200i internal 
temperature is too high.
• Power off the X-200i and 
allow it to cool down. 
Ensure that the intake and 
exhaust vents are not 
blocked. Turn the 
projector back on. If the 
problem persists, please 
contact Runco Technical 
Support for assistance. 
ISSUE LED lights solid red.
• Fans are not working 
properly or power-on 
self-test has failed (Note). 
• Please contact Runco 
Technical Support for 
assistance. 
When displaying 3D content, 
crosstalk or “ghosting” can be 
seen — that is, the left eye is 
perceiving some of what the 
right eye should be seeing or 
vice versa. 
• Rear-projection installation 
uses second-surface 
mirrors that are producing 
faint, secondary 
reflections. 
• Always use first-surface 
mirrors in your 
rear-projection installation. 
With 3D glasses, image per-
spective is reversed — that is, 
“left-eye“ frames appear in the 
right lens and vice versa. 
• Incorrect L-R Swap 
setting. 
• Change the L-R Swap 
3D glasses do not work. 
• Glasses are not charged 
and/or communicating 
with the Active3D Emitter. 
• Refer to Using the 3D 
Table 5-1. Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Solution
Note: You can obtain more detailed information about the cause of the error condition using 