Axor 39144XX1 User Manual

Page of 8
·     Remove the inserts from the hot and 
cold plaster shields.
·     Cut the plaster shields so that they 
extend 1/16” from the wall.  Seal 
around the shields with a suitable, 
non-staining, waterproof bathroom 
sealant.
·     Lever handle version only:  
Remove the hot and cold 
cartridges using a 17 mm deep 
socket wrench.  Replace them 
with the 1⁄4 turn ceramic cartridges 
included with the trim kit.  The hot 
cartridge is marked with notches 
on the wrench flats.
·     On the spout outlet, measure the 
distance from the brass rough-in 
to the end of the plaster shield.  
Record this measurement (“X”).  
Add 1 7/8” to this measurement.  
Measure the spout adapter.  Mark 
a point X + 1 7/8” from the o-
ring end of the adapter.  Cut the 
adapter at this point.
·     Wrap the threads with several 
layers of Teflon® thread tape.  
Screw it into the spout port. 
·     Measure the distance from the 
plaster shield to the end of the 
spout adapter.  It should measure 
1 3/8”.