EXTERNAL INSPECTION AND CLEANING
Cleaning the Air Intake Chamber Screen:
  •  At least twice annually the air intake chamber   
      screen should be inspected for any dust or      
 
debris that may have accumulated on the   
 
 louvers. 
NOTE: If the water heater is located in an area 
that is subjected to lint, pet hair or dirt, it may be 
necessary to check the air intake chamber screen 
more frequently.
  •  Use a vacuum cleaner with a hose attachment  
 
to remove any dust or debris that may have    
 
accumulated on the screen.
Air Intake Chamber 
Screen
Figure 24.
Cleaning the Combustion Chamber and Air 
Diverter Assembly:
  •  Follow procedure outlined in “Removing Inner  
 
Door/Manifold/Burner Assembly”, page 41.
  •  Use a vacuum cleaner/shop vac to remove    
 
all loose debris in the combustion chamber.    
 
Use compressed air to clear any dust or    
 
 
debris that may have accumulated on the air   
 diverter 
assembly.
•  Reassemble following the procedure under    
 
“Installing Inner Door/Manifold/Burner   
 
 
 
Assembly”, page 42.
Figure 25.
INNER DOOR/
MANIFOLD/BURNER 
ASSEMBLY
AIR DIVERTER
ASSEMBLY
INST
ALL
REMOVE
COMBUSTION 
CHAMBER