Site location
Select a location near the center of the water piping 
system. It must be installed indoors and in a vertical 
position on a level surface. 
The water heater should be located in an area not 
subject to freezing temperatures. Water heaters located 
in unconditioned spaces (i.e., attics, basements, etc.) 
may require the water piping and drain piping to be 
insulated to protect against freezing. The drain and 
controls must be easily accessible for operation and 
service. 
Do not use this water heater in conjunction with a spa 
or hot tub.
Note:  
Local codes and requirements in your area may 
require the water heater to be installed such that the 
bottom element is elevated from the floor at least 18 
inches.
4
Note:  The water heater shall be located so it is not 
subject to physical damage by moving vehicles or area 
flooding.
State of California
Note:  The water heater must be braced, anchored, or 
strapped to avoid moving during an earthquake. Contact 
local utilities for code requirements in your area or call 
1-877-817-6750 and request instructions.
Important:  The water heater should be located in an 
area where leakage of the tank or connections will not 
result in damage to the area adjacent to the water 
heater or to lower floors of the structure. Due to the 
normal corrosive action of the water, the tank will 
eventually leak after an extended period of time. 
Also any external plumbing leak, including those 
from improper installation, may cause early 
failure of the water tank due to corrosion if not 
repaired. If the homeowner is uncomfortable with 
making the repair a qualified service technician 
should be contacted.
 It is recommended that a 
suitable drain pan be installed under the water heater 
as shown below. This pan is to protect the property 
from damage which may occur from normal 
condensate formation on the tank or leaks in the tank 
and pipe connections. The pan must limit the water 
level to a maximum depth of 2-1/2 inches and be two 
inches wider than the heater and piped to an 
adequate drain. Locate the water heater near a 
suitable indoor drain. Outdoor drains are subject to 
freezing temperatures which can obstruct the drain 
line. The piping should be at least 3/4”ID and pitched 
for proper drainage.
Under no circumstance will the manufacturer or 
seller of this water heater be held liable for any 
water damage is caused by your failure to follow 
these instructions.
2 1/2” Max
Pipe to
adequate
drain
At least 2” inches greater than
the diameter of the water
heater.
Figure 1
Residential Garage
Installation
Vehicle
Stop
Drain
Drain
Pan