Whirlpool 188412 User Manual

Page of 15
Installation Checklist
Water Heater Location
!
Centrally located with the water piping system.
!
Located indoors and in a vertical position.
!
Protected from freezing temperatures.
!
Provisions made to protect the area from water 
damage.
!
Drain pan installed and piped into an adequate 
drain.
!
Sufficient clearance to service the water heater.
Water System Piping
!
Temperature and pressure relief valve properly 
installed with a discharge line plumbed to an open 
drain and protected from freezing.
!
All piping properly installed and free of leaks.
!
Water heater completely filled with water.
!
Closed system pressure buildup precautions 
installed.
!
Tempering valve installed per manufacturer’s 
instructions.
Electrical Connections
!
Wiring and connections comply with all applicable 
codes.
!
Water heater and electrical supply are properly 
grounded.
!
Proper overload fuse or circuit breaker protection 
installed.
Wiring Diagram
240 Volts Only
5.  Ground the water heater by connecting the 
grounding wire from the electrical service ground to 
the (green) ground screw located in the junction 
box. Note:  Only use 10 gauge wires for electrical 
connections and a 30 ampere double pole breaker.
 6. Connect the red and black wires to the incoming 
power leads.
 7. Replace cover and secure with screws.
8
Figure 6
Field Wiring
240V - 30A Service
Junction Box
Cover