Screen reference 
1032
Trunk Group 
17
Type
This field specifies the signaling type to be used with TN760B (or later release), 
TN722 (with any suffix), TN767, TN2140 (when the Trunk Signaling Type field 
is 
cont
), TN437, TN439, TN464 with any suffix, or TN458 circuit packs.
The Type column appears when the Trunk Signaling Type field is blank or cont. 
The Type column does not display if the Trunk Signaling Type field is dis
!
CAUTION:
Customers should not attempt to administer this field. Please contact your 
Lucent representative for assistance.
Ans Delay
!
CAUTION:
Customers should not attempt to administer this field. Please contact your 
Lucent representative for assistance
This delay serves two purposes:
It ensures that the answer supervision signal is valid and not a secondary 
delay-dial or wink-start signal.
Valid entries
Usage
t1 stan
t1 comp
t5rev
The value of 
t5 rev
 is allowed only for the TN760D vintage 10 
or later. When Type is 
t5 rev
, Mode must be 
e&m
.
type 5
Valid entries
Usage
20
 to 
5100
 in 
increments of 
20 
Specifies the length of time (in ms) your switch will wait 
before it sends answer supervision for incoming calls on tie 
trunks using the TN722A or later, TN760 (B, C, or D), TN767, 
TN464 (any suffix), TN437, TN439, TN458, or TN2140 circuit 
packs. 
blank
Same as setting the field to zero.