Screen reference 
557
Crisis Alert System Parameters 
17
Retries
Displays when the Alert Pager field is 
y
.
Retry Interval (sec)
Displays when the Alert Pager field is 
y
. This field is not used unless the Retries 
field is 
1
-
10
.
Main Number
The main phone number to the location or a location code. This field is optional 
and does not require an entry. Displays when the Alert Pager field is 
y
.
Pager Number
Displays when the Alert Pager field is 
y
. One of these fields must have a number 
or the screen cannot be submitted.
Valid entries
Usage
-
 10
The number of times the system tries to send out the alert 
message in case of an unsuccessful attempt. This increases the 
chances that the pager receives a crisis alert message.
Valid entries
Usage
30 
-
 60
The administrable time period (in seconds) between retries. If 
an attempt to call the pager fails, the retry call attempts after the 
retry interval period.
Valid entries
Usage
digits
 0-9
(dash)
Enter a number up to 15 digits to identify the location where the 
crisis alert call originated. It can be the main number to the 
location or a numerical identification. Any dashes are for 
display purposes only and not included in the message sent to 
the pager. This entry is the last group of digits displayed in the 
pager message.
Valid entries
Usage
1 to 15 digits
Any dashes are for display purposes only and not included in 
the message sent to the pager. One of the pager number fields 
must have a number of the screen cannot be submitted.