Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-405
CLSFY-PT (Call Classifier Port) 
9
CLSFY-PT (Call Classifier Port)
The TN744 Call Classifier is a service circuit pack that provides specialized tone 
detection capabilities to support the Outbound Call Management (OCM) and 
Inbound Call Management (ICM) features. The TN744 supports both A-law and 
Mu-law companding.
The TN744 has eight ports (CLSFY-PTs), each capable of supporting call 
classification, touch-tone reception and MFC-tone generation and detection. The 
CLSFY-PT maintenance object implements a set of tests designed to ensure 
proper operation of the Call Classifier.
Error Log Entries and Test to Clear Values
Notes:
a. There are two possible alarm levels for this error type: MAJOR and 
MINOR. A major alarm is raised if the total number of call classifier ports 
currently in-service is less than or equal to 1/2 of the administered 
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier 
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack 
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
CLSFY-PT
1
MAJOR
test port UUCSSpp sh
Call Classifier Port
CLSFY-PT 
MINOR
test port UUCSSpp sh
Call Classifier Port
CLSFY-PT 
WARNING
test port UUCSSpp sh
Call Classifier Port
Table 9-171.
Call Classifier Port (CLSFY-PT) Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1
any
Tone Detector 
Audit/Update Test (#43)
MAJOR/ 
MINOR(a)
ON
test port UUCSSpp r 2
18
busyout port
WARNING
OFF
release port UUCSSpp
257(b)
17666
Tone Detection Audit 
Update Test (#43)
MAJOR/ 
MINOR(a)
ON
test port UUCSSpp r 3
513(c)
any
Tone Detection Verification 
Test (#42)
MAJOR/ 
MINOR(a)
ON
test port UUCSSpp r 3