9-406
CLSFY-PT (Call Classifier Port) 
9
threshold number. Otherwise, a minor alarm is raised. In either case, run 
the short test sequence on the alarmed port and follow the error code 
procedures for the individual tests.
The in-service threshold number for alarming call classifier ports is 
administered using the change system-parameters maintenance 
command. For details, refer to 
Chapter 8, ‘‘Maintenance Commands’’
.
1. Issue these commands in order: busyout boardreset board
release board. The board reset is required to reload on-board RAM 
associated with the TN744’s DSPs. This takes all 8 tone detector 
ports out of service for a few seconds. Only 4 of the 8 would be out 
of service due to the alarm. (There are 5 tone detectors on each of 
the two DSPs.) Other than the unlikely potential of running out of 
tone detector resources in the switch, there is no other effect when 
the board is reset.
2. Test the board (test board UUCSS long).
3. If the test still fails, replace the board.
b. The CLSFY-PT lost its translation. Testing the CLSFY-PT is sufficient to 
reload its translation. If testing the call classifier port does not clear the 
error, then the call classifier circuit pack containing the defective call 
classifier port should be replaced.
c. This error indicates the call classifier port is having problems detecting 
call classification tones or detecting and generating R2-MFC tones This is 
usually accompanied by failures of some incoming or outgoing calls. If 
this error type is persistently logged, then replace the call classifier circuit 
pack containing the defective CLSFY-PT.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the following tables. By 
clearing error codes associated with the 
Tone Detection Verification Test, for 
example, you may also clear errors generated from other tests in the testing 
sequence.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Tone Detection Verification Test(#42)
X
X
ND
Tone Detection Audit/Update Test(#43)
X
X
ND