Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-436
CO-TRK (Analog CO Trunk) 
9
CO Demand Diagnostic Test (#3)
For ground start trunks, port circuit pack relays are operated and checks are 
made to see if the port can detect and apply ground on the Tip lead. This test 
also verifies that there is no external ground on the Ring lead. In the absence of 
other failures, the circuit pack should be replaced only if this test fails with the CO 
line disconnected.
For the TN2147, this test also checks the on-board programmable transmission 
circuits that allow the circuit pack to support transmission characteristics of 
several different countries.
2002
FAIL
Seizure portion of test failed due to hardware problem. Fault is usually 
caused by a disconnected trunk.
1. If the CO Demand Diagnostic Test (#3) also failed, display the Hardware 
Error Log. If the CO Demand Diagnostic Test failed because it could not 
detect ground (indicated by Error Type 1281 in the Hardware Error Log) 
AND Error Type 3329 or 3585 appears in the Hardware Error Log (with 
the same last occurred time as Error Type 1281 and 1537), replace the 
circuit pack.
2. Check trunk wiring to ensure good connection; repeat test if wiring 
correction made.
3. Locate another identical CO trunk and swap its wiring with one under 
test. Repeat test on both trunks and determine if problem follows trunk 
or remains at original port. If problem follows trunk, refer problem to CO. 
If problem remains at port, replace circuit pack and repeat test.
1009
PASS
Detected tone was not pure dial tone. No action required.
PASS
Trunk was seized, and dial tone was detected. User-reported troubles on 
this port should be investigated by using other port tests and by examining 
trunk or external wiring.
0
NO 
BOARD
The test could not relate the internal ID to the port.
1. Check to ensure that the board translations are correct. Translate the 
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage 
between the internal ID and the port.
Table 9-181.
TEST #0 Dial Tone Test  — Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page