9-437
CO-TRK (Analog CO Trunk) 
9
Table 9-182.
TEST #3 CO Demand Diagnostic Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be 
busy with a valid call. 
1. Use the display port UUCSSpp command to determine the trunk 
group/member number of the port. Use the status trunk command to 
determine the service state of the port. If the service state indicates that 
the port is in use, then the port is unavailable for certain tests. You must 
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
1004
ABORT
The port was seized by a user for a valid call. 
1. Use the display port UUCSSpp command to determine the trunk 
group/member number of the port. Use the status trunk command to 
determine the service state of the port. If the service state indicates that 
the port is in use, then the port is unavailable for certain tests. You must 
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
1005
ABORT
Test inapplicable to present configuration. This is a normal condition.
1018
ABORT
Test has been disabled via administration.
1. For this test to run, the 
Maintenance Tests?
 field on the trunk group 
form must be set to 
n
. The form is accessed with the change trunk-group 
grp# command.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page