DAT-LINE (Data Line Port) 
9
9
DAT-LINE (Data Line Port)
The TN726 Data Line circuit pack has 8 ports, each of which supports an RS-232 
interface to asynchronous Customer Premises Equipment (CPE). Each of these 
ports and the equipment connected to it constitute a data line. For DT-LN-BD 
(Data Line Circuit Pack) errors, refer to "XXX-BD (Common Port Circuit Pack)". 
Check circuit pack-level errors first since the usability of the ports depend on the 
health of the circuit pack.
Data line ports are administered at the terminal with the add data-module 
command. The data module type is 
data-line. The list data-module command 
will list all administered data modules in the system. See “PDATA-PT” for details 
on how data lines are used as system ports.
The TN750 Announcement circuit pack also has one data line-type port on it. 
This data line port is used for saving and restoring announcements. For a 
description of this feature and repair instructions for the TN750, refer to 
“ANN-BD”.
NOTE:
If the tests for the data line port in question pass, and user-reported 
complaints persist, there is probably an external problem. Test the 
asynchronous data unit (ADU), following the procedures outlined in 
User 
Manual Z3A Asynchronous Data Unit, 555-401-701. If the ADU appears to 
be working properly, check the external wiring, and then check the 
customer equipment.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier 
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack 
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of 
MO
DAT-LINE
MINOR
test port UUCSSpp l
Data Line Port
DAT-LINE
WARNING
test port UUCSSpp l
Data Line Port