Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-458
DAT-LINE (Data Line Port) 
9
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indicate any hardware 
malfunction. Run the Short Test Sequence and investigate errors.
b. Indicates the circuit pack has been removed or has been insane for more 
than 11-minutes. To clear the error, reseat or replace the circuit pack.
c. Error type 769 indicates that the data line circuit pack found an error in the 
transmit/receive circuitry of an administered data line when the circuit 
pack was inserted. Perform the following:
1. Enter busyout board UUCSS for the circuit pack on which the port 
resides.
2. Enter reset board UUCSS. Check the Error Log to determine if 
Error Type 769 is logged again for DAT-LINE. Make sure that the 
Active Alarms Only
 field is set to 
n
.
If error type 769 reappears, replace the data line circuit pack. If 
Error Type 769 does not reappear, proceed to Step 3.
3. Enter release board UUCSS.
Table 9-190.
Data Line Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1
Digital Looparound 
Test (#171)
MINOR
ON
test port UUCSSpp s r 2
15(a)
Any
Audit Update Test 
(#36)
18
0
Busyout port 
UUCSSpp
WARNING
OFF
rel port UUCSSpp
130 (b)
None
WARNING
ON
test port UUCSSpp sh
257
Conference Circuit 
Test (#7)
MINOR
ON
test port UUCSSpp l r 2
513
NPE Crosstalk Test 
(#6)
MINOR
ON
test port UUCSSpp l r 2
769(c)
40983
None