Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-483
DID-TRK (Direct Inward Dial Trunk) 
9
DID-TRK (Direct Inward Dial Trunk)
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the 
trunk group administration form. Settings must be compatible with the local 
environment and with parameter settings on the far-end. Refer to 
DEFINITY. 
Enterprise Communications Server Release 5.4 Administration and Feature 
Description, for information on how to administer trunks. The Application 
Notes section of that book shows the correct settings for administrable 
timers and other parameters on a country-by-country basis.
Direct Inward Dial trunks connect the switch to the CO, and allow outside parties 
to call directly to an extension in the system. DID trunk circuit packs support 
eight incoming-only ports. Each port provides an interface between the 2-wire 
analog CO line and the 4-wire TDM bus on the switch. 
DID Trunk Operation
The DID port receives three to five digits from the CO that are used to directly 
connect an outside caller to the called station without assistance from an 
attendant. For each call, the CO switch signals the system by opening and 
closing individual DID loops (one of the eight ports), causing the starting or 
stopping of loop current.
DID Trunk Testing
The system uses four tests of on-board circuitry to diagnose the health of the 
trunk. These are described in the following sections. Additionally, in-line testing 
which can generate errors, is performed while a call is in progress. See the Error 
Log table for
 a description of these errors. These errors may be reproduced by 
placing a call on the trunk and checking the Hardware Error Log.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier designation
(A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). pp
is the two digit port number (01, 02, ...).
Full Name of MO
DID-TRK
MAJOR
2
2.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by the
set options command and that at least 75 percent of the trunks in this trunk group are
alarmed.
test port 
UUCSSpp l
DID Trunk
DID-TRK
MINOR
test port 
UUCSSpp l
DID Trunk
DID-TRK
WARNING
None
DID Trunk