Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-484
DID-TRK (Direct Inward Dial Trunk) 
9
Problems detected during signaling may be caused by off-board faults in the CO 
switch or connections for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an 
incoming call seizes a port that is being tested, the test will abort and the 
incoming call will proceed.
For transmission and signaling standard specification, refer to 
Digital PBX 
Standards, RS4648.
Ports Out-of-Service without Errors or Alarms
A common trouble on DID trunks that produces no errors or alarms occurs when 
the CO busies out (disconnects) the port. This situation occurs when the CO 
thinks there are problems with the DID port. In this case, no incoming calls will be 
possible through this port. This may result in complaints from outside callers 
trying unsuccessfully to call in. This problem can be diagnosed by listing 
measurements on lightly used trunks. If a particular port is detected as not in 
use, a call to the CO will be necessary to get the connection back in service.
Error Log Entries and Test to Clear Values
Table 9-199.
DID Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port 
UUCSSpp sh r 1
1(a)
Any
None
WRN
OFF
1(b)
57476
None
WRN
OFF
1(c)
57477
None
WRN
OFF
1(d)
57483
None
WRN
OFF
15(e)
Any
Port Audit Update 
(#36)
18
0
busyout trunk 
grp/mbr
WRN
OFF
release trunk 
grp/mbr
130(f)
None
WRN
ON
test trunk 
grp/mbr
257(g)
57472
None
WRN
OFF
257(h)
57473
None
WRN
OFF
257(i)
57474
None
WRN
OFF
257(j)
57475
None
WRN
OFF
513(k)
57392
None
MIN/ WRN
2
OFF
510(l)
57393
None
Continued on next page