Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Initialization and Recovery 
4-3
Hot Restart 
4
4. Use the save translations command to make the changes permanent.
!
CAUTION:
To avoid potential loss of servce, ensure that your system’s 
translations are protected by saving them to the PCM/CIA card.
Hot Restart
This reset occurs only on a duplicated SPE during a 
planned SPE interchange.
Reset Level 1 (Warm Restart)
Duration
Up to 1.5 minutes
Causes
reset system interchange command
(use of the contention-override or health-override options 
causes a reset level 1 or higher)
SPE interchange requested by scheduled maintenance 
Effects
Call service is unaffected.
Yellow LEDs light on new active SPE and go out on the new 
standby.
Memory shadowing is turned off.
Remote access port (SYSAM-RMT) login is dropped.
Duration
Up to 10 seconds, typically 2 seconds
Causes
reset system 1 command
Spontaneous SPE interchange (those caused by hardware 
faults)
Software faults that are non-service affecting
Abort of planned SPE interchange
Hardware bus errors
TN1655 Packet Interface faults