DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Initialization and Recovery 
4-5
Reset Level 2 (Cold-2 Restart) 
4
Reset Level 2 (Cold-2 Restart)
Duration
Up to 3.75 minutes
Causes
reset system 2 command
Escalation from reset level 1
An attempted reset level 1 during a PNC interchange
TDM-bus clock recovery on the PPN 
Spontaneous interchange into an unrefreshed standby SPE
Effects
All system and application links are dropped.
All calls are dropped.
Non-translation feature data, such as Automatic Wakeup calls, 
are lost and must be reentered.
All G3-MT logins, including remote access and system port 
logins, are dropped.
Initialization firmware runs diagnostics and displays results on 
the G3-MT screen.
SPE memory shadowing is turned off, leaving the standby SPE 
unavailable for service for several minutes.
All hardware components, except PNC components, are reset, 
including the EPNs. All standby Expansion Interfaces, and the 
active EI in the PPN are reset. SNIs, SNCs, DS1Cs and active 
EIs in the EPNs are not reset.
If the PNC is duplicated, a global refresh of the standby PNC is 
performed after the reset.
All busied out maintenance objects are released and must be 
rebusied, if so desired.
Circuit packs are reinitialized, (translations are verified by 
comparison to physical board locations).
If core dump is enabled for this reset level, reset is delayed 
until the core dump is complete.
Error and alarm logs are preserved, but all alarms are resolved 
except for STBY-SPE and busyouts.