Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-530
DIOD-TRK (DIOD Trunk) 
9
DIOD-TRK (DIOD Trunk)
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the 
trunk group administration form. Settings must be compatible with the local 
environment and with parameter settings on the far-end. Refer to DEFINITY 
Communications System Generic 3 V2 Implementation, 555-230-653 for 
information on how to administer trunks. The Application Notes section of 
that book shows the correct settings for administrable timers and other 
parameters on a country-by-country basis.
Direct inward and outward dial (DIOD) trunks are 2-wire analog lines to the CO 
which support the following services:
Both incoming and outgoing CO calls
DID trunk
DID trunk and 1-way outgoing DIOD
TN429 DIOD trunk circuit packs provide eight ports for loop-start CO trunks and 
serve as an interface between the 2-wire analog CO line and the 4-wire TDM bus 
on the switch.
Loop Start Operation
Idle State: Tip = ground, Ring = CO Battery
Outgoing Call
1. PBX Off-Hook (Seize Message): Closes the Tip-Ring Loop CO Response: 
DC loop current + Dial tone
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier designation (A, 
B, C, D, or E). 
SS is the number of the slot in which the circuit pack resides (01 to 21). pp is 
the two digit port number (01, 02, ...).
Full Name of MO
DIOD-TRK
MAJOR
2
2.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by the 
set options command and that at least 75 percent of the trunks in this trunk group are 
alarmed.
test port 
UUCSSpp  l
DIOD  Trunk
DIOD-TRK
MINOR
test port 
UUCSSpp  l
DIOD  Trunk
DIOD-TRK
WARNING
test port 
UUCSSpp  l
DIOD  Trunk