Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-532
DIOD-TRK (DIOD Trunk)
9
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error and does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors.
errors.
c. Aux data 57376
—
No loop current on incoming call
Aux data 57424
—
No loop current on outgoing call
These errors cause the Dial Tone Test (#0) to run and are only considered
a problem if the Dial Tone Test fails (in which case Error Type 1537 also
appears). In this case, the trunk may be put in ‘‘Ready-for-Service’’ state
(shown as ‘‘disconnected’’ by status command), which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its procedures.
a problem if the Dial Tone Test fails (in which case Error Type 1537 also
appears). In this case, the trunk may be put in ‘‘Ready-for-Service’’ state
(shown as ‘‘disconnected’’ by status command), which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its procedures.
Table 9-217.
DIOD Trunk Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear
Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port sh
15 (b)
any
Port Audit Update Test (#36)
18
0
Busyout trunk
grp/mbr
WARNING
release trunk
769 (a)
57392
None
MAJ/MIN/WRN
2
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
ON
1537
Dial Tone Test (#0)
MAJ/MIN/WRN
2
ON
test port long r 2
1793
Looparound and
Conference Test (#33)
Conference Test (#33)
MAJ/MIN/WRN
2
ON
test port long r 3
2049
NPE Cross Talk Test (#6)
MAJ/MIN/WRN
2
ON
test port long r 3
2561 (a,d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3073 (a,c)
57424
None
3585 (a,c)
57424
None