Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-666
DS1 CONV-BD 
9
Clear Firmware-Counters Command
DS1 CONV firmware generates error reports autonomously. This takes place 
independently of technician-demanded tests. Therefore, the test board UUCSS 
clear command will not affect the error status reported by firmware. The clear 
firmware-counters command will clear all on-board firmware-detected 
errors unconditionally.
The clear firmware-counters UUCSS command sends a downlink message to 
the DS1 CONV circuit packs, causing them to clear out their firmware error 
counters and failure databases. Once the firmware failure database is cleared, 
the failure audit test (#949) will pass. If problems still exist, the firmware will 
increment its error counters and the failure audit test will begin failing again.
This command should not be used as a replacement for the repair procedures 
associated with the hardware error log entries. This command may be useful if a 
problem has been fixed and off-board alarms associated with the problem are 
still active.
Downtime required when upgrading to TN1654 
DS1 CONV Circuit Packs
!
WARNING:
Upgrading from TN574 DS1 CONV circuit packs to TN1654 DS1 CONV 
circuit packs will require down time for the affected EPN.
The TN1654 DS1 Converter circuit pack is not compatible with the TN573 SNI 
circuit pack, the TN574 DS1 CONV board, the Y-cable used to connect to the 
TN574 DS1 CONV board or pre-G3V5 software. All DS1 CONV boards and 
Y-cables must be upgraded. If the EPN is remoted via a Center-Stage Switch, the 
connected SNI must also be upgraded. A TN573B or later suffix SNI board must 
be used when connecting to a TN1654 DS1 CONV board.
The fiber-link administration for the TN574 DS1 CONV Complex must be removed 
via the remove fiber-link command. The change circuit-pack form must be 
updated to reflect that TN1654 boards are now being used. The TN1654 DS1 
CONV Complex can then be administered via the add fiber-link command.
Replacing a DS1 CONV Circuit Pack with the
same type DS1 CONV circuit pack
Simplex
PNC
!
WARNING:
Do not power down a Switch Node carrier to replace a circuit pack.