Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-667
DS1 CONV-BD 
9
!
WARNING:
Replacing a Switch Node Interface, Switch Node Clock, Expansion 
Interface or DS1 Converter circuit pack on a simplex system disrupts 
service. The service effect can range from outage of a single EPN to outage 
of the entire system.
!
WARNING:
A DS1 Converter Complex must consist of two TN574 boards or two 
TN1654 boards. A TN574 cannot be combined with a TN1654 in the same 
DS1 CONV Complex.
Replacing a DS1 CONV Circuit Pack with the
same type DS1 CONV circuit pack
Duplicated
PNC
!
WARNING:
On a system with duplicated PNC, synchronization may be provided over a 
combination of active and standby components. This condition is indicated 
by an OFF-BOARD WARNING alarm against TDM-CLK with error type 
2305. Repairs to standby PNC in this state may disrupt service. Otherwise, 
if the active PNC is functional, replacement of a standby component will not 
disrupt service.
Steps
Comments
Enter busyout board UUCSS
UUCSS represents the cabinet-carrier-slot 
address of the circuit pack to be replaced. 
A G3-MT logged in at the EPN Maintenance 
circuit pack will remain active in spite of the 
busyout.
Replace the circuit pack with the same 
DS1 CONV board type.
Wait for the circuit pack to reset
Red and green LEDs will light and then go 
out.
Enter release board UUCSS
CAUTION:
 Do not busyout any Expansion 
Interface circuit pack after this point.
Enter test alarms long clear for category 
exp-intf.
Wait 5 minutes for SNI-BD, FIBER-LK 
AND DS1C-BD alarms to clear, or enter 
clear firmware counters a-pnc