DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-669
DS1 CONV-BD 
9
!
WARNING:
A TN573B or later suffix board must be used when connecting a SNI board 
to a TN1654 DS1 Converter board.
Steps
Comments
Enter list fiber-link
Determine the fiber-link number associated 
with the two TN574 circuit packs to be 
upgraded.
Enter busyout fiber-link <fiber #>
fiber # represents the fiber-link number 
associated with the TN574 DS1 CONV 
Complex that is being upgraded to a TN1654 
DS1 CONV Complex.
Enter remove fiber-link <fiber #>
Remove the TN574 DS1 CONV circuit 
packs from the system.
Replace the TN574 Y-cables with 
appropriate TN1654 Y-cables.
Replace the removed TN574 DS1 CONV 
circuit packs with TN1654 DS1 CONV 
circuit packs. Prior to installing the 
TN1654 boards, review the prior 
section, 
If a TN1654 DS1 CONV board is 
connected to an SNI board, upgrade the 
SNI to a TN573B or greater.
Wait for the circuit packs to reset
Red and green LEDs will light and then go 
out.
Enter change circuit-packs <cabinet 
#>
. Update the form to show that 
TN1654 boards are now being used 
instead of TN574 boards. Also update 
the connected SNI, if applicable, to 
suffix B.
cabinet # represents the cabinet associated 
with a DS1 CONV board. The appropriate 
change circuit-packs form needs to be 
updated for both DS1 CONV boards. Also, if 
needed, re-add translations for connected EI 
boards.
Enter add fiber-link <fiber #> to re-add 
the fiber-link using TN1654 DS1 CONV 
circuit packs. See the 
Definity Enterprise 
Communications Server, Release 5, 
Implementation Manual, 555-230-302, 
for details on TN1654 administration.
fiber # represents the fiber-link number 
associated with the TN574 DS1 CONV 
Complex that is being upgraded to a TN1654 
DS1 CONV Complex
Enter test alarms long clear for 
category exp-intf.