9-693
DT-LN-BD (Data Line Circuit Pack) 
9
DT-LN-BD (Data Line Circuit Pack)
Refer to "XXX-BD (Common Port Circuit Pack)" for circuit pack level errors. See 
also DAT-LINE (Data Line Circuit Port) for related line information.
MO Name (In 
Alarm Log
Alarm 
Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier 
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack 
resides (01 to 21).
Full Name of MO
DT-LN-BD
MIN
test board UUCSS sh
Data Line Circuit Pack
DT-LN-BD
WRN
test board UUCSS sh
Data Line Circuit Pack