Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-695
DTMR-PT (Dual Tone Multi-Frequency Receiver Port) 
9
Error Log Entries and Test to Clear Values
Notes:
a. There are two possible alarm levels for this error: Major alarm and Minor 
alarm. A Major alarm is raised if the total number of DTMR ports currently 
in service is less than or equal to 1/2 of the administered threshold 
number. Otherwise, a Minor alarm is raised. In either case, run the Short 
Test Sequence against the DTMR port and follow the error code 
procedures for the individual tests.
The threshold number of DTMR ports for service is administered using the 
change system-parameters maintenance command.
b. The DTMR port lost its translation. Testing the DTMR port is sufficient to 
reload its translation. If testing the DTMR port does not clear the error, 
then the Tone Detector circuit pack containing the defective DTMR port 
should be replaced.
c. This error indicates the DTMR port is having problems detecting 
touch-tone digits. If this error is being constantly logged, then the Tone 
Detector circuit pack containing the defective DTMR port should be 
replaced.
d. This error type indicates that the circuit pack has been removed or has 
been insane for at least 11 minutes. To clear the error, reinsert or replace 
the circuit pack.
Table 9-269.
Dual Tone Multi-Frequency Receiver Port (TTR) Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1
17664
Tone Detector Audit/ 
Update Test (#43)
MAJOR/ 
MINOR(a)
ON
test port UUCSSpp r 2
18
0
busyout port UUCSSpp
WARNING
ON
release port UUCSSpp
130 (d)
None
WARNING
ON
test port 
UUCSSpp sh r 2
257 (b)
17666
Tone Detector Audit/ 
Update Test (#43
MAJOR/ 
MINOR(a)
ON
test port UUCSSpp r 3
513 (c)
Any
Tone Detection 
Verification Test (#42
MAJOR/ 
MINOR(a)
ON
test port UUCSSpp r 3