Maintenance Object Repair Procedures 
9-770
ETH-PT (Control LAN Ethernet) 
9
1125
ABORT
Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or 
status link n).
2. If the Ethernet link is not in service, release the link (release link n or 
release port UUCSSpp).
3. Repeat the test.
1959
ABORT
Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times. 
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2100
ABORT
Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
FAIL
Link integrity lost due to problem with attachment of Ethernet cable to the 
port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to Ethernet port 
and to the bus.
3. Verify the CLAN circuit pack link integrity LED is glowing. 
4. Retry the test.
5. If problem persists, refer to Ethernet Local Looparound Test (#1278) 
repair procedures.
PASS
The Ethernet Link Integrity Test (#1282) detects good connections.
Table 9-299.
TEST #1282 Link Integrity Inquiry Test — Continued