Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-773
ETR-PT (Enhanced Tone Receiver Port) 
9
ETR-PT (Enhanced Tone Receiver Port) 
NOTE:
Replacing the tone/clock circuit pack requires a special procedure which is 
described in “TONE-BD (Tone-Clock Circuit Pack)”. That section also 
describes the LED display for this board.
The TN2182 is a combined Tone Generator/Tone Detector board. It provides 
8 Enhanced Tone receiver (ETR) ports. Each of these ports provides the 
functions previously found individually on DTMR-PTs, GPTD-PTs and CLAS-PTs 
ports. Thus each port on the TN2182 may be used for any tone detection function 
that was previously done by TN748, TN420 or TN744 Tone detection boards.
The TN2182 provides Mu-law or A-law tone detection capability.
Since the TN2182 also provides Tone/Clock function only one (or two if your 
system is duplicated) TN2182 circuit packs may be present in a port network. 
Thus if more tone detection resources are needed, the additional resources must 
be provided by TN748, TN420 or TN744 circuit packs.
Error Log Entries and Test to Clear Values
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation (A, B, 
C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). pp is the two 
digit port number (01, 02, ...).
Full Name of MO
ETR-PT
MAJOR
test port UUCSSpp sh
Enhanced Tone Receiver Port
ETR-PT
MINOR
test port UUCSSpp sh
Enhanced Tone Receiver Port
ETR-PT
WARNING
test port UUCSSpp sh
Enhanced Tone Receiver Port
Table 9-301.
ETR-PT Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1 (a)
any
Tone Detector 
Audit/Update Test 
(#43)
MAJ/ MIN
ON
test port UUCSSpp r 2
18
busyout port
WARNING
OFF
release port UUCSSpp
Continued on next page