DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-797
EXP-INTF (Expansion Interface Circuit Pack) 
9
Replacing an EI Circuit Pack— Duplicated PNC
!
WARNING:
On a system with duplicated PNC, synchronization may be provided over a 
combination of active and standby components. This condition is indicated 
by an OFF-BOARD WARNING alarm against TDM-CLK with error type 
2305. Repairs to standby PNC in this state may disrupt service. Otherwise, 
if the active PNC is functional, replacement of a standby component will not 
disrupt service.
6.
Wait 5 minutes for SNI-BD, FIBER-LK 
AND DS1 CONV-BD alarms to clear, 
or enter clear firmware counters 
a-pnc
Step
Action
Explanation/Caution
1.
Enter status pnc
Verify that the component to be replaced is on 
the standby PNC.
2.
Enter busyout pnc
3.
Enter busyout board UUCSS
UUCSS represents the cabinet-carrier-slot 
address of the circuit pack to be replaced.
4.
Replace the circuit pack
5.
Enter release board UUCSS
CAUTION:
 Do not busyout any Expansion 
Interface circuit pack after this point.
6.
Enter test alarms long clear for 
category exp-intf
7.
Wait 5 minutes for SNI-BD, SNI-PEER, 
FIBER-LK, and DS1 CONV alarms to 
clear, or enter clear firmware 
counters <a-pnc or b-pnc>
Use the letter designation of the pnc that holds 
the replaced component (the standby pnc).
8.
Enter status pnc
If either PNC state-of-health is not “functional,” 
consult the 
‘‘PNC-DUP (PNC Duplication)’’
 
section.
9.
Enter release pnc
Continued on next page
Step
Action
Explanation/Caution
Continued on next page